The material for this adjustment is limited to:
- a numerical multimeter.
- a screwdriver HF or by defect a piece of stripped printed
circuit of its copper.
Open Tx Ampli side / X-ray / Tx..synthé
You must discover this:

Locate the reel L111 and the variable capacitator C145 then the point of control W105.....
Attention at the time of the catch of measurements on this
point it does not have there much place... hi.
The adjustment is very simple:
- To program on channel 00 the frequency simplex of 144,500
MHz
- To put the multimeter on a gauge allowing measurement
uninterrupted tensions from approximately 3 to 4 volts.
- the point test for measurements in tension will be
W105...... (Traversée white which goes from part RX/TX to the
amplifier.)
Remain in reception:
- Check the presence of the tension of 3.00v on this point.
- If you have this value more or less regulate the core of
L111 to obtain 3.00v
Pass in emission:
- On the same point of control (W105) the value must be of
3.00v also.
- If it is not the case regulate the condenser C145 for with
the same value as çi-top.
The adjustments are finished, you can close again.
Return to the page of presentation